fire alarm system >> Mircom >> Addressable Modules Mix-500 Series ................................................................................................................................................................................................................................................................... Mircom’s intelligent module products are designed to meet a wide range of applications. The monitor and control modules can be used to supervise and activate sounders, strobes, door closers, pull stations, water flow switches, conventional smoke detectors and more. The modules are addressed with easy-to-use rotary code switches and mount in a standard 4” x 4” x 2 1/8” junction box.
Intelligent Addressable Monitor Module (MIX-M500M) The Intelligent Addressable Monitor Module (MIXM500M) provides an address for a group of UL/ULC Listed normally open (N.O.) initiating devices, such as heat detectors, beam smoke detectors, 4-wire smoke detectors, waterflow switches, manual pull stations, etc. wired in a Class A (Style D) or Class B (Style B) initiating circuit. The MIX-M500M has an activated red LED.
Intelligent Addressable Dual Monitor Module (MIX-M500DM) The Intelligent Addressable Dual Monitor Module (MIX-M500DM) provides two independent 2-wire initiating device circuits at two separate, consecutive addresses. It is capable of monitoring two separate Class B (Style B) circuits simultaneously, making it ideal for water flow and tamper switch monitoring. The MIX-500DM has a single activated red LED that is common to either circuit.
Intelligent Addressable Mini-Monitor Module (MIX-M501M) The Intelligent Addressable Mini Monitor Module provides an address for a group of UL/ULC Listed Normally Open (N.O.) initiating devices, such as heat detectors, projected beam smoke detectors, 4-wire smoke detectors, waterflow switches, manual pull stations, etc. wired in a Class B (Style B) initiating circuit.
Intelligent Addressable Interface Module (MIX-M502M) The MIX-M502M provides the same features as the MIX-M500M but also allows for the use of multiple, conventional 2-wire smoke detectors in the circuit. This module requires a reset table signal power source. The MIX-M502M internally supervises the separate power source. The red LED indicates when the module is activated. All two-wire detectors that are monitored must be UL/ULC compatible with the MIX-M502M module.
Intelligent Addressable Supervised Control Module (MIX-M500S) The MIX-M500S Control module provides supervised monitoring of wiring to signal devices that require an external power supply to operate, such as horns, strobes, bells or speaker isolators. Conventional signals will require a 24 VDC power source and speakers will require an audio input. The MIX-M500S does not supervise the power source. A UL/ULC EOL relay such as the A77-716B(A) is required. The red LED will illuminate when the module is activated. The module is capable of Class A (Style Z) or Class B (Style Y) supervision.
Intelligent Addressable Relay Module (MIX-M500R) The Intelligent Addressable Relay Module connects to the same loop as the initiating devices and provides two isolated sets of Form-C contacts. The module allows the FX-2000 fire alarm control panel to switch these contacts on command. The MIXM500R has an activated red LED which follows the state of the relay contacts. Fault Isolator Module (M500X) The M500X Fault Isolator Module is used to
protect the system against wir General Specifications Operating Voltage 15-32 VDC Communication Line Loop Impedance 40 .max. Temperature Range 32° to 120°F (0° to 49°C) Relative Humidity 10% to 93%: noncondensing Dimensions MIX-M501M: 1.7”H x 2.7”W x 0.5”D Others: 4.65”H x 4.25”W x 1.1”D Shipping Weight M501M: 1.2 oz (37g) Others: 6.3 oz (196g) MIX-M500DM Specifications Standby Current 750 μA max. @ 24 VDC (one communication every 5 sec. with 47k EOL) Alarm Current 970 μA max. (one communication every 5 sec.) 6 mA (with LED latched on) End-of-Line Resistance 47 k (two included) MIX-M500R Specifications Standby Current 300 μA @ 24 VDC (one communication every 5 sec. with LED enabled) LED Current 5.5 mA (with LED latched on) Relay Contact Ratings 3.0 A @ 30 VDC resistive 0.9 A @ 110 VDC resistive 0.9 A @ 125 VAC resistive 0.5 A @ 125 VAC inductive (PF=.35) 0.7 A @ 75 VAC inductive (PF=.35) MIX-M502M Specifications Standby Current 300 μA max @ 24 VDC (one communication every 5 sec. with LED enabled) External Power Supply 18-28 VDC (100 mV ripple max.) End-of-Line Resistance 3.9 k (included) External Supply Standby Current 11.5 mA @ 24 VDC (nominal) External Supply Alarm Current 80 mA @ 24 VDC (nominal) M500X Specifications Standby Current 450 μA max Isolation Current 5 mA max Fault Detection Delay 250 ms min. Fault Detection Threshold 4 Volts Line Restoration Threshold 7 Volts MIX-M500M, MIX-M500S, MIX-M501M Specifications Standby Current 400 μA max @ 24 VDC (one communication every 5 sec. with 47k EOL) 550 μA max @ 24 VDC (one communication every 5 sec. with EOL<1k) 5.5 mA (with LED latched on) End-of-Line Resistance 47 k (included) Ordering Information MIX-M500M Intelligent Addressable Monitor Module MIX-M501M Intelligent Addressable Mini-Monitor Module MIX-M502M Intelligent Addressable Interface Module MIX-500DM Intelligent Dual Monitor Module MIX-M500S Intelligent Addressable Supervised Control Module MIX-M500R Intelligent Addressable Relay Module M500X Fault Isolator Module | |