fire alarm system >> cTEC

...................................................................................................................................................................................................................................................................

 

Offering high performance at a competitive price, the AFP one or two loop analogue addressable fire panel supports System Sensor, Nittan or Apollo XP95 protocols. Fullycompliant with EN54 Parts 2 and 4, it's wide range of features include 16 zonal alarmLEDs (expandable to 32), four separate independently programmable sounder circuits andan integral 24V 3amp switch mode power supply. The AFP can be programmed on-site viatactile switches on the panel front or via an easy to use, low-cost upload/download PCprogramme. Other features include a 999 event memory, delay timer and phasedevacuation facilities, sophisticated test and maintenance facilities and a comprehensive'auto-learn' facility allowing the panel to self-configure to devices connected to the loop.

16 zonal alarm leds provided as standard,expandable to 32 via AFP703 extension LED kit.

Compatible with Apollo XP95, System Sensor or Nittan protocols.

Panel supplied with one integral loop driver, expandable to two via AFP702 plug-on loop driver.

Easy-to-read 80 character back-lit display

40 characters of custom text available per device

Four separate independently programmable sounder circuits rated at a total of 3A.

Powerful short circuit protected loop drivers.

Up to 32 loop driven sounders per loop.

Integral 24V 3A EN54 switch mode psu, rated @ 185-260Vac, 50-60 Hz.

Alert, Reset, Silence and Class Change inputs.

Fire, Fault, Pre-alarm, Reset and +24V Aux. outputs

Remote Signal Output (to remote manned centre).

Space for 7AHr sealed lead acid batteries.

Earth fault monitoring.

999 event memory.

Programmable sounder/remote output delay facilities (per zone)

Phased evacuation facility

RS232 port provided for connection to external serial printer or upload/download PC.

One AFP711 Network Driver Card (fitted to theRS485 port on the master panel) allows the connection of up to 15 AFP Repeaters per system (Repeaters are not compatible with AFPE Economy Panels).

Sophisticated test and maintenance facilities.

Panel can be programmed on-site via tactile switches on panel front or via an easy to use, low-cost upload/ download PC programme.

Comprehensive ‘Auto-Learn’ facility allows panel to self configure to devices connected to the loop.

Push button entry code access protection.

Detailed description of faults on LCD display.

Intuitive language-free legend on main label allows cost-effective customizing of smaller label with customers own logo and/or foreign language text.

Specifications

 POWER SUPPLY SPECIFICATION

Mains supply voltage

230 Va.c. 10% 50/60Hz

Internal power supply

27Vd.c.

Total output current limited to

3A @ 230 Va.c. (1.5A on AFPE)

Auxiliary power output

27 Vd.c. Nominal monitored

for failure

Yes

Battery charger monitored for failure

Yes

Batteries monitored for disconnection & failure

Yes

Quiescent current drain (1 loop unloaded)

<80mA

Quiescent current drain (2 loop unloaded)

<100mA

Earth fault monitoring

Yes - any conductor to Earth

Temperature compensated charging

Yes

 

DETECTOR LOOP DRIVER SPECIFICATION

Maximum number of Loop Drivers allowed

2 (1 on AFPE)

Maximum cable length per loop

1Km

Line Fault monitored for Open Circuit

Yes

Line Fault monitored for Short Circuit

Yes

Onboard loop isolators with LED indication when active

Yes

Auto-Polling from each loop end

Yes

Maximum allowable loop impedance (each conductor)

20 Ohm

Maximum cable capacitance

.27uF

Maximum loop output current

350mA

Peripheral modules supported

Yes - as detailed in manual.

Max no. addressable points per loop (Apollo XP95)

126

Max no. addressable points per loop (System Sensor)

99 sensors + 60 modules

 

LOOP POWERED SOUNDERS

Number of programmable Groups

15

Maximum number per loop (Apollo XP95)

32

Maximum number per loop (System Sensor)

32

 

PANEL CONVENTIONAL SOUNDER CIRCUIT SPECIFICATION

Number of Programmable circuits

4

End of Line Resistor Value

6800 Ohm 5% Tol. 0.25W

Line Fault monitored for Open Circuit

Yes

Line Fault monitored for Short Circuit

Yes

Outputs fused at

1 Amp

Maximum total output current all outputs

3 Amps (1.5Amps on AFPE)

Maximum No. of Bells @ 25 mA

120 (60 on AFPE)

Maximum No. of electronic sounders @ 20 mA

150 (75 on AFPE)

 

AUXILIARY OUTPUTS

Max sink current

100mA each (300mA total)

Type

Open Collector

Max open circuit voltage

27Vd.c.

Reset Output

Active low during reset cycle

Remote Output (to manned centre)

Active low during any fire condition + isolate/delay facility

Pre-Alarm Output

Active low during any pre-alarm condition

Fire1 Output

Active low during any fire condition

Fire2 Output

Active low during any fire condition unless silenced

Fault

Active low when NO faults are present - failsafe to o/c

24v Aux Power Output

1 Amp - fuse

 

FUSES

Mains Fuse

1A HRC Ceramic 20mm

Sounder Outputs (F1, F2, F3, F4)

1A F 20mm

Auxiliary Output (F5)

1A F 20mm

Battery Fuse

3A F 20mm

All fuses compliant to IEC (EN60127 PT2)

 

 

AUXILIARY INPUTS

Reset

0V Trigger (active low)

Silence

0V Trigger (active low)

Class Change (Evacuate)

0V Trigger (active low)

Alert (Phased Evacuate)

0V Trigger (active low)

 

CONNECTION BLOCK

Plug on Type - largest acceptable conductor size = 1.5mm

 

FRONT PANEL CONTROLS & INDICATORS

Control Buttons

Silence, Reset, Evacuate

Scroll/Menu Access Buttons

Up (1); Down (2); Accept (3); Abort (4)

Liquid Crystal Display

2 lines x 40 Characters (backlit)

LED Indicators

1 x General Fire (red)

 

16 x Zonal Fire, expandable to 32 (all red)

 

1 x System Energised (green)

 

1 x PreAlarm (amber)

 

1 x Remote Output Activated (red)

 

1 x Menus Accessed (amber)

 

1 x Disablement (amber)

 

1 x Test (amber)

 

1 x Remote Output Disabled (amber)

 

1 x Silenced (amber)

 

1 x General Fault (amber)

 

1 x System Fault (amber)

 

1 x Sounder Fault (amber)

 

1 x PSU Fault (amber)

 

APPROXIMATE DIMENSIONS

Back Box (W x H x D)

410 x 250 x 80mm (metal)

Lid (W x H x D)

435 x 270 x 5mm (metal) 439 x 274 x 7mm (plastic)

Weight (without batteries)

4.5Kg

 

CABLING

Fire proof, screened cable (min. size 1mm)

 

PROGRAMMING & PRINTER CONNECTION

2 x RS232

1 x Plug on connector and 1 x 0.1 Molex header

 

PROGRAMMING METHODS

On site using the AFP's fascia buttons

On or off-site using a Windows-based PC running the AFP upload/download software.

 

MENU ACCESS LEVELS

Access Level 1

Scroll events

Access Level 2

 Silence, Reset, Evacuate

 

Override delays

 

View active Fire, Pre-Alarms, Faults & Disablements

 

Disable / Enable Points, Zones and Outputs

 

Set time and date

 

Change User PIN code

 

Review event log

Access Level 3

View and edit Point information

 

View and assign a zone's sounder configuration

 

Set delays / Assign phased evacuation

 

Set next maintenance date

 

Change User and Engineer PIN code

 

Invoke Commissioning utilities

 

Invoke Test and Maintenance utilities

 

Clear event log

 

SITE SPECIFIC DATA

User and Engineer Pin Code

40 Characters free text for company name, etc

Next due maintenance date

Data protected by internal manual link

Configuration may be edited via front panel buttons or a PC programmed running Windows 95.

 

We reserve the right to alter product specifications without prior notice.
Errors and omissions excepted.